Boron, Serum/Plasma Test (0711SP)

Boron, Serum/Plasma Test (0711SP)

Analysis Code 0711SP 
Test Name Boron, Serum/Plasma 
Test Includes Boron 
Compound Synonym(s) Borate 
Purpose Exposure Monitoring/Investigation; This test is New York State approved. 
Category Metal/Element 
Method(s) Inductively Coupled Plasma/Optical Emission
Spectrometry (ICP/OES) 
Specimen Requirements 2 mL Serum or Plasma 
Transport Temperature Refrigerated 
Specimen Container Plasma: Royal Blue top tube, plastic (Trace metal-free; EDTA), Serum: Royal Blue top tube, plastic (Trace metal-free; No additive) 
Special Handling Promptly centrifuge and separate Serum or Plasma into an acid washed plastic screw capped vial using approved guidelines. 
Light Protection Required Not Required 
Stability Room Temperature: 30 day(s)
Refrigerated: 30 day(s)
Frozen (-20 °C): 30 day(s) 
*Rejection Criteria Glass container. Polymer gel separation tube (SST or PST). 
Day(s) Test Set-up / TAT [ICP/OES] Monday / 7 days 
Suggested CPT Code 83018 
**Minimum Volume 0.7 mL 
Test Summary Sheet Generate  

You are viewing Boron, Serum/Plasma Test (0711SP)
*Rejection criteria pertain to clinical specimen submissions only.
**Stated minimum volume allows for a single analysis. Repeat analysis will not be performed.


A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9