Isobutanol, Serum/Plasma Test (2436SP)

Isobutanol, Serum/Plasma Test (2436SP)

Analysis Code 2436SP 
Test Name Isobutanol, Serum/Plasma 
Test Includes Isobutanol 
Compound Synonym(s) Iso-Butanol; Iso-Butyl Alcohol; Isobutyl Alcohol 
Purpose Exposure Monitoring; This test is New York State approved. 
Category Environmental/Occupation Toxin 
Method(s) Headspace Gas Chromatography (GC) 
Specimen Requirements 2 mL Serum or Plasma 
Transport Temperature Refrigerated 
Specimen Container Plastic container (preservative-free) 
Special Handling Serum: Collect sample in Red top tube
Plasma: Collect sample in Lavender top tube (EDTA) or Pink top tube.
Collect sample using alcohol free skin preparation. Promptly centrifuge and separate Serum or Plasma into a plastic screw capped vial using approved guidelines. Ensure that container remains tightly sealed. 
Light Protection Required Not Required 
Stability Room Temperature: Undetermined
Refrigerated: Undetermined
Frozen (-20 °C): Undetermined 
*Rejection Criteria Polymer gel separation tube (SST or PST). 
Day(s) Test Set-up / TAT [Headspace GC] Tuesday Thursday Sunday / 3 days 
Suggested CPT Code 84600 
**Minimum Volume 0.7 mL 
Test Summary Sheet Generate  

You are viewing Isobutanol, Serum/Plasma Test (2436SP)
*Rejection criteria pertain to clinical specimen submissions only.
**Stated minimum volume allows for a single analysis. Repeat analysis will not be performed.