Isopropyl Ether, Serum/Plasma Test (2450SP)

Isopropyl Ether, Serum/Plasma Test (2450SP)

Analysis Code 2450SP 
Test Name Isopropyl Ether, Serum/Plasma 
Test Includes Isopropyl Ether 
Purpose Overexposure/Poisoning Determination; This test is New York State approved. 
Category Environmental/Occupation Toxin 
Method(s) Headspace Gas Chromatography (GC) 
Specimen Requirements 2 mL Serum or Plasma 
Transport Temperature Refrigerated 
Specimen Container NMS Labs has no experimental or literature-based data regarding the choice of specific specimen collection containers for this test. 
Special Handling Promptly centrifuge and separate Serum into a plastic screw capped vial using approved guidelines. Ensure that container remains tightly sealed. 
Light Protection Required Not Required 
Stability Room Temperature: Undetermined
Refrigerated: Undetermined
Frozen (-20 °C): Undetermined 
*Rejection Criteria Polymer gel separation tube (SST or PST). 
Day(s) Test Set-up / TAT [Headspace GC] Tuesday Thursday Sunday / 3 days 
Suggested CPT Code 84600 
**Minimum Volume 0.7 mL 
Test Summary Sheet Generate  

You are viewing Isopropyl Ether, Serum/Plasma Test (2450SP)
*Rejection criteria pertain to clinical specimen submissions only.
**Stated minimum volume allows for a single analysis. Repeat analysis will not be performed.


A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9

This test can be ordered online

Price: $156.00