Phenobarbital, Serum/Plasma Test (8633SP)

Phenobarbital, Serum/Plasma Test (8633SP)

Analysis Code 8633SP 
Test Name Phenobarbital, Serum/Plasma 
Test Includes Phenobarbital 
Compound Synonym(s) Luminal┬« 
Purpose Identification and Quantitation; This test is New York State approved. 
Category Anticonvulsant, Sedative 
Method(s) Gas Chromatography/Mass Spectrometry
(GC/MS) 
Specimen Requirements 2 mL Serum or Plasma 
Transport Temperature Refrigerated 
Specimen Container Plastic container (preservative-free) 
Special Handling Serum: Collect sample in Red top tube
Plasma: Collect sample in Lavender top tube (EDTA) or Pink top tube.
Promptly centrifuge and separate Serum or Plasma into a plastic screw capped vial using approved guidelines. 
Light Protection Required Not Required 
Stability Room Temperature: 14 day(s)
Refrigerated: 14 day(s)
Frozen (-20 ┬░C): 3 month(s) 
*Rejection Criteria Polymer gel separation tube (SST or PST). 
Day(s) Test Set-up / TAT [GC/MS] Tuesday Thursday / 3 days 
Suggested CPT Code 80184 
**Minimum Volume 0.7 mL 
Test Summary Sheet Generate  

You are viewing Phenobarbital, Serum/Plasma Test (8633SP)
*Rejection criteria pertain to clinical specimen submissions only.
**Stated minimum volume allows for a single analysis. Repeat analysis will not be performed.