Platinum, Serum/Plasma Test (3783SP)

Platinum, Serum/Plasma Test (3783SP)

Analysis Code 3783SP 
Test Name Platinum, Serum/Plasma 
Test Includes Platinum 
Purpose Exposure Monitoring/Investigation; Therapeutic Drug Monitoring; This test is New York State approved. 
Category Metal/Element 
Method(s) Inductively Coupled Plasma/Mass
Spectrometry(ICP/MS) 
Specimen Requirements 1 mL Serum or Plasma 
Transport Temperature Refrigerated 
Specimen Container Plastic container (Acid washed or Trace metal-free) 
Special Handling Serum: Collect sample in Royal Blue top tube (Trace metal-free; No additive)
Plasma: Collect sample in Royal Blue top tube (Trace metal-free; EDTA)
Promptly centrifuge and separate Serum or Plasma into an acid washed plastic screw capped vial using approved guidelines. 
Light Protection Required Not Required 
Stability Room Temperature: 2 month(s)
Refrigerated: 2 month(s)
Frozen (-20 °C): 2 month(s) 
*Rejection Criteria Polymer gel separation tube (SST or PST). 
Day(s) Test Set-up / TAT [ICP/MS] Friday / 1 day 
Suggested CPT Code 83018 
**Minimum Volume 0.4 mL 
Test Summary Sheet Generate  

You are viewing Platinum, Serum/Plasma Test (3783SP)
*Rejection criteria pertain to clinical specimen submissions only.
**Stated minimum volume allows for a single analysis. Repeat analysis will not be performed.


A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9