Titanium, Urine Test (4486U)

Titanium, Urine Test (4486U)

Analysis Code 4486U 
Test Name Titanium, Urine 
Test Includes Titanium 
Purpose Exposure Monitoring/Investigation; This test is New York State approved.

Note: On 06/14/2013 a change in the method for measuring titanium in urine has resulted in a shift with the reported findings. To compare a previous finding to a current result, multiply the old value by 1.1 and then subtract 14 for an approximate corresponding new value. The reporting limit for the new method is 10 mcg/L; therefore, any measured value less than 10 mcg/L will be reported as 'None Detected'. 
Category Metal/Element 
Method(s) Inductively Coupled Plasma/Mass
Spectrometry(ICP/MS) 
Specimen Requirements 2 mL Urine 
Transport Temperature Frozen 
Specimen Container Plastic container (Acid washed or Trace metal-free) 
Special Handling Avoid exposure to gadolinium-based contrast media for 48 hours prior to sample collection. 
Light Protection Required Not Required 
Stability Room Temperature: Not Stable
Refrigerated: Not Stable
Frozen (-20 °C): 30 day(s) 
*Rejection Criteria Received Room Temperature. Received Refrigerated. 
Day(s) Test Set-up / TAT [ICP/MS] Wednesday / 1 day 
Suggested CPT Code 83018 
**Minimum Volume 0.6 mL 