Method(s)
High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS)
Suggested CPT Code(s)
80354
80364
New York State Approval Status

Approved

Turnaround Time

4 days

Test Includes
1 Methoxyacetylfentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
2 Acrylfentanyl Acryloylfentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
3 para-Fluorofentanyl 4-Fluorofentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
4 ortho-Fluorofentanyl 2-Fluorofentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
5 2-Furanylfentanyl Fu-F; Furanylfentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
6 U-47700 U-4 High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
7 Carfentanil Carfentanyl; Wildnil® High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
8 Cyclopropylfentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
9 trans-3-Methylfentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
10 cis-3-Methylfentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
11 Isobutyrylfentanyl Isobutyrfentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
12 Butyrylfentanyl Butyrfentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
13 para-Fluoroisobutyrylfentanyl 4F-Isobutyrylfentanyl; FIBF High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS
14 Valerylfentanyl Pentylfentanyl High Performance Liquid Chromatography/ Tandem Mass Spectrometry (LC-MS/MS) ng/mL 0.05 NPS

Compliance Statement
This test was developed and its performance characteristics determined by NMS Labs. It has not been cleared or approved by the US Food and Drug Administration.
Sample Type
Blood
Requested Volume
2 mL
Minimum Volume
0.7 mL
Special Handling
None
Sample Container
Gray top tube (Sodium Fluoride / Potassium Oxalate)

Additional Collection Instructions

Transport Temperature
Frozen
Light Protection
Not Required
Rejection Criteria
Received Room Temperature. Received Refrigerated.

Rejection criteria pertain to clinical sample submissions only.

Stability
Room Temperature: Not Stable
Refrigerated: 2 day(s)
Frozen (-20 °C): 14 day(s)

The CPT Codes provided in this document are based on AMA Guidelines and are for informational purposes only. NMS Labs Does not assume responsibility for billing errors due to Reliance on the CPT Codes listed in this document.