Test Summary Sheet for:

Purpose
Exposure Monitoring/Investigation
Method(s)
Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)
Suggested CPT Code(s)
82175
83825
84255
New York State Approval Status

Approved

Turnaround Time

8 days

Test Includes
1 Arsenic Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 5 Metal/Element
2 Bismuth Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 0.5 Metal/Element
3 Lead Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/dL 5 Metal/Element
4 Antimony Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 1 Metal/Element
5 Thallium Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 0.5 Metal/Element
6 Mercury Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 1.5 Metal/Element
7 Selenium Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 20 Metal/Element

Specimen Type
Blood
Requested Volume
3 mL
Minimum Volume
1.4 mL
Special Handling
Clotted Blood specimens are not acceptable. Collect sample in Glass Container (see Specimen Container).
Avoid seafood consumption for 48 hours prior to sample collection. Submit in container with a non-Heparin based anticoagulant. Tubes containing Heparin based anticoagulants are not acceptable.
Specimen Container
Royal Blue top tube (Trace metal-free; EDTA)

Additional Collection Instructions

Transport Temperature
Refrigerated
Light Protection
Not Required
Rejection Criteria
Plastic container. Light Green top tube (Lithium Heparin). Tan top tube - glass (Sodium Heparin). Royal Blue top tube (Trace metal-free; Sodium Heparin). Gray top tube (Sodium Fluoride / Potassium Oxalate). Green top tube (Sodium Heparin). Lavender top tube (EDTA).

Rejection criteria pertain to clinical specimen submissions only.

Stability
Room Temperature: 14 day(s)
Refrigerated: 14 day(s)
Frozen (-20 °C): 14 day(s)
1 Arsenic Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 5 Metal/Element
2 Bismuth Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 0.5 Metal/Element
3 Lead Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/dL 5 Metal/Element
4 Antimony Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 1 Metal/Element
5 Thallium Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 0.5 Metal/Element
6 Mercury Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 1.5 Metal/Element
7 Selenium Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) mcg/L 20 Metal/Element

Interface Map

LOINC® Information

The CPT Codes provided in this document are based on AMA Guidelines and are for informational purposes only. NMS Labs Does not assume responsibility for billing errors due to Reliance on the CPT Codes listed in this document.

*The information contained in this document represents database configurations, as they will appear on the effective date listed above.