Method(s)
Gas Chromatography/Mass Spectrometry (GC/MS)
Suggested CPT Code(s)
84600
New York State Approval Status

Approved

Turnaround Time

7 days

Test Includes
1 1,1-Difluoroethane Freon 152a Gas Chromatography/Mass Spectrometry (GC/MS) mcg/mL 0.14 Inhalant
2 1,1,1,2-Tetrafluoroethane Dymel 134a; Genetron 134a; HFC-134a; norflurane; R134a; Suva 134a; tetrafluoroethane Gas Chromatography/Mass Spectrometry (GC/MS) mcg/mL 0.14 Inhalant

Test Also Known As
DFE; Dust off; TFE
Compliance Statement
This test was developed and its performance characteristics determined by NMS Labs. It has not been cleared or approved by the US Food and Drug Administration.
Sample Type
Blood
Requested Volume
2 mL
Minimum Volume
0.7 mL
Special Handling
Ensure that container remains tightly sealed.
Sample Container
Gray top tube (Sodium Fluoride / Potassium Oxalate), Lavender top tube (EDTA)

Additional Collection Instructions

Transport Temperature
Refrigerated
Light Protection
Not Required
Rejection Criteria
None

Rejection criteria pertain to clinical sample submissions only.

Stability
Room Temperature: 7 day(s)
Refrigerated: 14 day(s)
Frozen (-20 °C): 14 day(s)

The CPT Codes provided in this document are based on AMA Guidelines and are for informational purposes only. NMS Labs Does not assume responsibility for billing errors due to Reliance on the CPT Codes listed in this document.